Generated by pacms.orera.in on date: 2024-05-09
: M/S. JB ASSETS PRIVATE LIMITED | : Private Company |
: U45201OR2012PTC016061 | :View |
NA | : Plot No.- N-6/178, IRC Village, Nayapalli, Bhubaneswar, Dist- khordha, Odisha- 751015 |
: Plot No- N-6/178, IRC Village, Nayapalli, Bhubaneswar, Dist- khordha, Odisha- 751015. | : jbassets.sales@gmail.com |
: 9438671073 | |
: AACCJ9444L | :View |
: 11 YEAR EXPRIENCE IN CONSTRUCTION SECTOR | : NA |
NA |
: JYOTIRANJAN BEHURIA | : |
: Director | : ALSPB7226L |
:PAN Card | : jyoti_behuria2008@rediffmail.com |
: GRADUATE | : 9438671073 |
: 11 YEAR EXPRIENCE IN CONSTRUCTION SECTOR | |
: Yes | : NA |
: BILASINI BEHURIA | : |
: Director | : AUHPB0011F |
:PAN Card | : jb.associates@rediffmail.com |
: GRADUATE | : 9438671073 |
: 11 YEAR EXPRIENCE IN CONSTRUCTION SECTOR | |
: Yes | : NA |
1. : JB PARK VIEW | : Residential | ||||
: plot no.609/1970, Maouza-Balianta | : Ongoing | ||||
: RP/19/2021/00592 | : NA | ||||
: Ownership | |||||
: S+4 RESIDENTIAL APARTMENT | NA | NA | : S+4 RESIDENTIAL APARTMENT | ||
: No |
: | : |
: | : |
: |
: No | : NA |
: No | : NA |
2. : JB PARK VIEW-II | : Residential | ||||
: PLOT NO.1062/2201, MOUZA-BALIANTA | : Ongoing | ||||
: RP/19/2021/00592 | : NA | ||||
: Ownership | |||||
: S+4 RESIDENTIAL APARTMENT | NA | NA | : S+4 RESIDENTIAL APARTMENT | ||
: No |
: | : |
: | : |
: |
: No | : NA |
: No | : NA |
3. : JB ESTELLA | : Plotted Scheme | ||||
: PLOT NO.295 & OTHERS, MOUZA-Benupur | : Ongoing | ||||
: RP/19/2023/00944 | : NA | ||||
: Ownership | |||||
: LAYOUT PLAN | NA | NA | : LAYOUT PLAN | ||
: No |
: | : |
: | : |
: |
: No | : NA |
: No | : NA |
: New | : JB POLARIS |
: Residential | : (Construction of B+G+10 Residential, Medium Income Housing, No. of Residential Units-79) |
: Khordha | : Bhubaneswar |
: 752063 | : Development Authority |
: Bhubaneswar Development Authority | |
: B+S+10 Residential, Medium Income Housing | : NA |
: Yes |
Serial No. | Particulars of the Person | Land/Plot Details | Share of the Person | Document Attached |
---|---|---|---|---|
1 | JYOTSNA SAHOO | PLOT NO.404/972 KHATA NO.238/89 | 42% ON BASE FAR (2 FAR) & 2% ABOVE BASE FAR (1.72 FAR) | Agreement Copy |
View | View |
Download site plan | 15-08-2026 |
16-08-2023 |
Sl. No. | Description of Conditions | Schedule date of compliance | Present Status |
---|---|---|---|
1 | Total Parking space measuring 2319.84 Sqm. as shown in the approved plan shall be left for parking of vehicles and no part of it will be used for any other purpose. | 15-08-2026 | NOT STARTED |
2 | The land over which construction is proposed is accessible by an approved means of access of 12.19 Mtr. in width. | 15-08-2026 | NOT STARTED |
3 | The applicant shall free gift 0 Sqm. wide strip of land to Bhubaneswar Development Authority for further widening of the road to the standard width as per CDP-2010, BDA. | 15-08-2026 | NOT STARTED |
4 | Permit the Authority to enter the building or premises, for which the permission has been granted at any reasonable time for the purpose of enforcing the regulations; | 15-08-2026 | NOT STARTED |
5 | Obtain, wherever applicable, from the competent Authority permissions/clearance required in connection with the proposed work; | 15-08-2026 | NOT STARTED |
6 | Give written notice to the Authority before commencement of work on building site in Form- V,periodic progress report in Form-VIII, notice of completion in Form-VI and notice in case of termination of services of Technical persons engaged by him. | 15-08-2026 | NOT STARTED |
7 | Obtain an Occupancy Certificate from the Authority prior to occupation of building in full or part. | 15-08-2026 | NOT STARTED |
8 | The applicant shall abide by the provisions of Rule no.15 of ODA (P&BS) Rules, 2020 with regard to third party verification at plinth level, ground level & roof level. Any deviation to the above shall attract penalty as per the provision of the same. | 15-08-2026 | NOT STARTED |
9 | In case the full plot or part thereof on which permission is accorded is agricultural kisam, the same may be converted to non-agricultural kisam under section- 8 of OLR Act before commencement of construction. | 15-08-2026 | NOT STARTED |
10 | The owner/applicant shall get the structural plan and design vetted by the institutions identified by the Authority for buildings more than 30 mtr height before commencement of construction. | 15-08-2026 | NOT STARTED |
11 | Wherever tests of any material are made to ensure conformity of the requirements of the regulations in force,records of the test data shall be kept available for inspection during the construction of building and for such period thereafter as required by the Authority. | 15-08-2026 | NOT STARTED |
12 | If the Authority finds at any stage that the construction is not being carried on according to the sanctioned plan or is in violations of any of the provisions of these regulations, it shall notify the owner and no further construction shall beallowed until necessary corrections in the plan are made and the corrected plan is approved. The applicant during the course of construction and till issue of occupancy certificate shall place a display board on his site with details and declaration. | 15-08-2026 | NOT STARTED |
13 | The owner/applicant/Technical Person shall strictly adhere to the terms and conditions imposed in the NOC/Clearances given by Fire Prevention officer/National Airport Authority/SEIAA, Ministry of Forest & Environment/PHED etc wherever applicable. | 15-08-2026 | NOT STARTED |
14 | Storm water from the premises of roof top shall be conveyed and discharged to the rain water recharging pits as per Rule 47 of ODA (Planning & Building Standards) Rules 2020. | 15-08-2026 | NOT STARTED |
15 | The space which is meant for parking shall not be changed to any other use and shall not be partitioned/closed in any manner | 15-08-2026 | NOT STARTED |
16 | 20% of the parking space in group housing/apartment building shall be exclusively earmarked for ambulance, fire tender, physically handicapped persons and outside visitors with signage as per norms under Rule 37 of ODA (Planning & Building Standards) Rules 2020. | 15-08-2026 | NOT STARTED |
17 | Plantation for one tree per 80 sqm of plot area made by the applicant as per provision under Rule 30 of ODA (Planning & Building Standards) Rules 2020. | 15-08-2026 | NOT STARTED |
18 | If the construction / development is not as per the approved plan / deviated beyond permissible norms, the performance security shall be forfeited and action shall be initiated against the applicant/builder / developer as per the provisions of the ODA Act, 1982 Rules and Regulations made there under. | 15-08-2026 | NOT STARTED |
19 | The Owner/ Applicant/Architect/Structural Engineer are fully and jointly responsible for any structural failure of building due to any structural/construction defects, Authority will be no way be held responsible for the same in what so ever manner. | 15-08-2026 | NOT STARTED |
20 | The applicant shall obtain infrastructural specification and subsequent clearance with regard to development of infrastructure from BMC/BDA before commencement of construction. | 15-08-2026 | NOT STARTED |
21 | ALl the stipulated conditions of the NOC/Clearances given by Project Director, DRDA, Khordha & CGWA shall be adhered to strictly. | 15-08-2026 | NOT STARTED |
22 | All the stipulated conditions of the Fire recommendations from FPW and Environmental Clearance if applicable shall be adhered to strictly. | 15-08-2026 | NOT STARTED |
23 | No storm water/water shall be discharged to the public road/public premises and other adjoining plots. | 15-08-2026 | NOT STARTED |
24 | The applicant shall abide by the terms and conditions of the NOC given by CGWA, EIDP given by Project Director, DRDA , Khordha. | 15-08-2026 | NOT STARTED |
25 | Adhere to the provisions of BDA (Planning & Building Standards) Regulation strictly and conditions thereto. | 15-08-2026 | NOT STARTED |
26 | All the passages around the building shall be developed with permeable pavers block for absorption of rain water and seepage in to the ground. | 15-08-2026 | NOT STARTED |
27 | Rain water harvesting structure and recharging pits of adequate capacity shall be developed to minimize the storm water runoff to the drain | 15-08-2026 | NOT STARTED |
28 | The applicant shall make own arrangement of solid waste management through micro compost plant within the project premises | 15-08-2026 | NOT STARTED |
29 | The applicant shall register this project before the ORERA as per affidavit submitted before commencement of work. | 15-08-2026 | IN PROGRESS |
30 | The applicant shall install Rooftop P.V. system as per BDA Regulations. | 15-08-2026 | NOT STARTED |
31 | The Authority shall in no way be held responsible for any structural failure and damage due to earthquake/cyclone/any other natural disaster. | 15-08-2026 | NOT STARTED |
32 | The number of dwelling units so approved shall not be changed in any manner. | 15-08-2026 | NOT STARTED |
33 | Minimum 30 % of parking spaces shall have facilities to enable Electrical Vehicle charging points. | 15-08-2026 | NOT STARTED |
34 | Applicant to allot the flats to beneficiaries belonging to MIG Category exclusively. | 15-08-2026 | NOT STARTED |
: Yes | : View |
Point No. | Latitude | Longitude |
---|---|---|
1 | 20°13'50.6"N | 85°44'38.2"E |
2 | 20°13'53.0"N | 85°44'38.7"E |
3 | 20°13'52.7"N | 85°44'39.8"E |
4 | 20°13'50.4"N | 85°44'39.4"E |
Description* | Scheduled date of completion | Current Status | Site Images |
---|---|---|---|
Site Development | 30-09-2023 | IN PROGRESS | |
Roof Casting | NA | NA | NA |
Ground Floor/Stilt Floor | 30-11-2023 | NOT STARTED | NA |
1 Floor | 31-01-2024 | NOT STARTED | NA |
2 Floor | 30-03-2024 | NOT STARTED | NA |
3 Floor | 31-05-2024 | NOT STARTED | NA |
4 Floor | 31-07-2024 | NOT STARTED | NA |
5 Floor | 30-09-2024 | NOT STARTED | NA |
6 Floor | 30-11-2024 | NOT STARTED | NA |
7 Floor | 31-01-2025 | NOT STARTED | NA |
8 Floor | 31-03-2025 | NOT STARTED | NA |
9 Floor | 31-05-2025 | NOT STARTED | NA |
10 Floor | 31-07-2025 | NOT STARTED | NA |
Brick Work & Plastering | NA | NA | NA |
Ground Floor/Stilt Floor | 30-03-2024 | NOT STARTED | NA |
1 Floor | 31-05-2024 | NOT STARTED | NA |
2 Floor | 31-07-2024 | NOT STARTED | NA |
3 Floor | 30-09-2024 | NOT STARTED | NA |
4 Floor | 30-11-2024 | NOT STARTED | NA |
5 Floor | 31-01-2025 | NOT STARTED | NA |
6 Floor | 31-03-2025 | NOT STARTED | NA |
7 Floor | 31-05-2025 | NOT STARTED | NA |
8 Floor | 31-07-2025 | NOT STARTED | NA |
9 Floor | 31-08-2025 | NOT STARTED | NA |
10 Floor | 30-09-2025 | NOT STARTED | NA |
Electrical Works | 28-02-2026 | NOT STARTED | NA |
Concealed Cabling including Plugs & switches | 28-02-2026 | NOT STARTED | NA |
Installation & Charging of Transformer | 28-02-2026 | NOT STARTED | NA |
Connection to Flats/Apartments | 28-02-2026 | NOT STARTED | NA |
PH works | 30-04-2026 | NOT STARTED | NA |
Laying of concealed Pipes | 30-04-2026 | NOT STARTED | NA |
PH Fittings | 30-04-2026 | NOT STARTED | NA |
Overhead Water Tanks | 30-04-2026 | NOT STARTED | NA |
Water Supply Connection to all units | 30-04-2026 | NOT STARTED | NA |
STP construction and completion | 30-04-2026 | NOT STARTED | NA |
Distempering & Colouring of all units and exteriors | 27-06-2026 | NOT STARTED | NA |
Fixation of doors and windows | 31-08-2026 | NOT STARTED | NA |
Scheduled Date of handing over possession | 31-12-2026 | NOT STARTED | NA |
Development of common areas, parks, gardens etc | 31-10-2026 | NOT STARTED | NA |
: Residential | |
: 79
|
|
Residential Flats/ House | |||||
---|---|---|---|---|---|
S. No. | Flat No./ House No. | ||||
Area in square metres |
Ownership | ||||
Carpet Area | Balcony Area | Exclusive Open Terrace Area | |||
1 | 101 | 62.96 | 7.00 | 0 | Promoter |
2 | 201 | 62.96 | 7.00 | 0 | Promoter |
3 | 301 | 62.96 | 7.00 | 0 | Promoter |
4 | 401 | 62.96 | 7.00 | 0 | Promoter |
5 | 501 | 62.96 | 7.00 | 0 | Promoter |
6 | 601 | 62.96 | 7.00 | 0 | Promoter |
7 | 701 | 62.96 | 7.00 | 0 | Promoter |
8 | 801 | 62.96 | 7.00 | 0 | Promoter |
9 | 901 | 62.96 | 7.00 | 0 | Promoter |
10 | 1001 | 62.96 | 7.00 | 0 | Promoter |
11 | 102 | 66.02 | 4.20 | 0 | Promoter |
12 | 202 | 66.02 | 4.20 | 0 | Promoter |
13 | 302 | 66.02 | 4.20 | 0 | Promoter |
14 | 402 | 66.02 | 4.20 | 0 | Promoter |
15 | 502 | 66.02 | 4.20 | 0 | Promoter |
16 | 602 | 66.02 | 4.20 | 0 | Promoter |
17 | 702 | 66.02 | 4.20 | 0 | Promoter |
18 | 802 | 66.02 | 4.20 | 0 | Promoter |
19 | 902 | 66.02 | 4.20 | 0 | Promoter |
20 | 1002 | 66.02 | 4.20 | 0 | Promoter |
21 | 103 | 77.29 | 8.42 | 0 | Promoter |
22 | 203 | 77.29 | 8.42 | 0 | Land Owner |
23 | 303 | 77.29 | 8.42 | 0 | Land Owner |
24 | 403 | 77.29 | 8.42 | 0 | Promoter |
25 | 503 | 77.29 | 8.42 | 0 | Promoter |
26 | 603 | 77.29 | 8.42 | 0 | Promoter |
27 | 703 | 77.29 | 8.42 | 0 | Promoter |
28 | 803 | 77.29 | 8.42 | 0 | Promoter |
29 | 903 | 77.29 | 8.42 | 0 | Promoter |
30 | 1003 | 60.24 | 3.06 | 0 | Promoter |
31 | 104 | 60.24 | 3.06 | 0 | Land Owner |
32 | 204 | 60.24 | 3.06 | 0 | Land Owner |
33 | 304 | 60.24 | 3.06 | 0 | Land Owner |
34 | 404 | 60.24 | 3.06 | 0 | Promoter |
35 | 504 | 60.24 | 3.06 | 0 | Promoter |
36 | 604 | 60.24 | 3.06 | 0 | Promoter |
37 | 704 | 60.24 | 3.06 | 0 | Promoter |
38 | 804 | 60.24 | 3.06 | 0 | Promoter |
39 | 904 | 60.24 | 3.06 | 0 | Promoter |
40 | 1004 | 60.88 | 3.06 | 0 | Promoter |
41 | 105 | 60.88 | 3.06 | 0 | Land Owner |
42 | 205 | 60.88 | 3.06 | 0 | Land Owner |
43 | 305 | 60.88 | 3.06 | 0 | Land Owner |
44 | 405 | 60.88 | 3.06 | 0 | Promoter |
45 | 505 | 60.88 | 3.06 | 0 | Promoter |
46 | 605 | 60.88 | 3.06 | 0 | Promoter |
47 | 705 | 60.88 | 3.06 | 0 | Promoter |
48 | 805 | 60.88 | 3.06 | 0 | Promoter |
49 | 905 | 60.88 | 3.06 | 0 | Promoter |
50 | 1005 | 70.11 | 4.00 | 0 | Promoter |
51 | 106 | 70.11 | 4.00 | 0 | Promoter |
52 | 206 | 70.11 | 4.00 | 0 | Land Owner |
53 | 306 | 70.11 | 4.00 | 0 | Land Owner |
54 | 406 | 70.11 | 4.00 | 0 | Promoter |
55 | 506 | 70.11 | 4.00 | 0 | Promoter |
56 | 606 | 70.11 | 4.00 | 0 | Promoter |
57 | 706 | 70.11 | 4.00 | 0 | Promoter |
58 | 806 | 70.11 | 4.00 | 0 | Promoter |
59 | 906 | 70.11 | 4.00 | 0 | Promoter |
60 | 1006 | 78.27 | 7.90 | 0 | Promoter |
61 | 107 | 78.27 | 7.90 | 0 | Promoter |
62 | 207 | 78.27 | 7.90 | 0 | Promoter |
63 | 307 | 78.27 | 7.90 | 0 | Promoter |
64 | 407 | 78.27 | 7.90 | 0 | Promoter |
65 | 507 | 78.27 | 7.90 | 0 | Promoter |
66 | 607 | 78.27 | 7.90 | 0 | Promoter |
67 | 707 | 78.27 | 7.90 | 0 | Promoter |
68 | 807 | 78.27 | 7.90 | 0 | Promoter |
69 | 907 | 78.27 | 7.90 | 0 | Promoter |
70 | 1007 | 72.61 | 5.95 | 0 | Promoter |
71 | 108 | 72.61 | 5.95 | 0 | Promoter |
72 | 208 | 72.61 | 5.95 | 0 | Promoter |
73 | 308 | 72.61 | 5.95 | 0 | Promoter |
74 | 408 | 72.61 | 5.95 | 0 | Promoter |
75 | 508 | 72.61 | 5.95 | 0 | Promoter |
76 | 608 | 72.61 | 5.95 | 0 | Promoter |
77 | 708 | 72.61 | 5.95 | 0 | Promoter |
78 | 808 | 72.61 | 5.95 | 0 | Promoter |
79 | 908 | 72.61 | 5.95 | 0 | Promoter |
Types of garages and parking | ||||||
---|---|---|---|---|---|---|
House No. | Type of Garage/ Parking allotted | Serial No., if any | Dimension (Length x Width) in Metres | Floor area in sq. metres | Garage/Parking area cost is included or additional | |
101 | Covered Parking | 101 | 3.5 M x 2.5 M | 8.75 SQM | Included | 201 | Covered Parking | 201 | 3.5 M x 2.5 M | 8.75 SQM | Included | 301 | Covered Parking | 301 | 3.5 M x 2.5 M | 8.75 SQM | Included | 401 | Covered Parking | 401 | 3.5 M x 2.5 M | 8.75 SQM | Included | 501 | Covered Parking | 501 | 3.5 M x 2.5 M | 8.75 SQM | Included | 601 | Covered Parking | 601 | 3.5 M x 2.5 M | 8.75 SQM | Included | 701 | Covered Parking | 701 | 3.5 M x 2.5 M | 8.75 SQM | Included | 801 | Covered Parking | 801 | 3.5 M x 2.5 M | 8.75 SQM | Included | 901 | Covered Parking | 901 | 3.5 M x 2.5 M | 8.75 SQM | Included | 1001 | Covered Parking | 1001 | 3.5 M x 2.5 M | 8.75 SQM | Included | 102 | Covered Parking | 102 | 3.5 M x 2.5 M | 8.75 SQM | Included | 202 | Covered Parking | 202 | 3.5 M x 2.5 M | 8.75 SQM | Included | 302 | Covered Parking | 302 | 3.5 M x 2.5 M | 8.75 SQM | Included | 402 | Covered Parking | 402 | 3.5 M x 2.5 M | 8.75 SQM | Included | 502 | Covered Parking | 502 | 3.5 M x 2.5 M | 8.75 SQM | Included | 602 | Covered Parking | 602 | 3.5 M x 2.5 M | 8.75 SQM | Included | 702 | Covered Parking | 702 | 3.5 M x 2.5 M | 8.75 SQM | Included | 802 | Covered Parking | 802 | 3.5 M x 2.5 M | 8.75 SQM | Included | 902 | Covered Parking | 902 | 3.5 M x 2.5 M | 8.75 SQM | Included | 1002 | Covered Parking | 1002 | 3.5 M x 2.5 M | 8.75 SQM | Included | 103 | Covered Parking | 103 | 3.5 M x 2.5 M | 8.75 SQM | Included | 203 | Covered Parking | 203 | 3.5 M x 2.5 M | 8.75 SQM | Included | 303 | Covered Parking | 303 | 3.5 M x 2.5 M | 8.75 SQM | Included | 403 | Covered Parking | 403 | 3.5 M x 2.5 M | 8.75 SQM | Included | 503 | Covered Parking | 503 | 3.5 M x 2.5 M | 8.75 SQM | Included | 603 | Covered Parking | 603 | 3.5 M x 2.5 M | 8.75 SQM | Included | 703 | Covered Parking | 703 | 3.5 M x 2.5 M | 8.75 SQM | Included | 803 | Covered Parking | 803 | 3.5 M x 2.5 M | 8.75 SQM | Included | 903 | Covered Parking | 903 | 3.5 M x 2.5 M | 8.75 SQM | Included | 1003 | Covered Parking | 1003 | 3.5 M x 2.5 M | 8.75 SQM | Included | 104 | Covered Parking | 104 | 3.5 M x 2.5 M | 8.75 SQM | Included | 204 | Covered Parking | 204 | 3.5 M x 2.5 M | 8.75 SQM | Included | 304 | Covered Parking | 304 | 3.5 M x 2.5 M | 8.75 SQM | Included | 404 | Covered Parking | 404 | 3.5 M x 2.5 M | 8.75 SQM | Included | 504 | Covered Parking | 504 | 3.5 M x 2.5 M | 8.75 SQM | Included | 604 | Covered Parking | 604 | 3.5 M x 2.5 M | 8.75 SQM | Included | 704 | Covered Parking | 704 | 3.5 M x 2.5 M | 8.75 SQM | Included | 804 | Covered Parking | 804 | 3.5 M x 2.5 M | 8.75 SQM | Included | 904 | Covered Parking | 904 | 3.5 M x 2.5 M | 8.75 SQM | Included | 1004 | Covered Parking | 1004 | 3.5 M x 2.5 M | 8.75 SQM | Included | 105 | Covered Parking | 105 | 3.5 M x 2.5 M | 8.75 SQM | Included | 205 | Covered Parking | 205 | 3.5 M x 2.5 M | 8.75 SQM | Included | 305 | Covered Parking | 305 | 3.5 M x 2.5 M | 8.75 SQM | Included | 405 | Covered Parking | 405 | 3.5 M x 2.5 M | 8.75 SQM | Included | 505 | Covered Parking | 505 | 3.5 M x 2.5 M | 8.75 SQM | Included | 605 | Covered Parking | 605 | 3.5 M x 2.5 M | 8.75 SQM | Included | 705 | Covered Parking | 705 | 3.5 M x 2.5 M | 8.75 SQM | Included | 805 | Covered Parking | 805 | 3.5 M x 2.5 M | 8.75 SQM | Included | 905 | Covered Parking | 905 | 3.5 M x 2.5 M | 8.75 SQM | Included | 1005 | Covered Parking | 1005 | 3.5 M x 2.5 M | 8.75 SQM | Included | 106 | Covered Parking | 106 | 3.5 M x 2.5 M | 8.75 SQM | Included | 206 | Covered Parking | 206 | 3.5 M x 2.5 M | 8.75 SQM | Included | 306 | Covered Parking | 306 | 3.5 M x 2.5 M | 8.75 SQM | Included | 406 | Covered Parking | 406 | 3.5 M x 2.5 M | 8.75 SQM | Included | 506 | Covered Parking | 506 | 3.5 M x 2.5 M | 8.75 SQM | Included | 606 | Covered Parking | 606 | 3.5 M x 2.5 M | 8.75 SQM | Included | 706 | Covered Parking | 706 | 3.5 M x 2.5 M | 8.75 SQM | Included | 806 | Covered Parking | 806 | 3.5 M x 2.5 M | 8.75 SQM | Included | 906 | Covered Parking | 906 | 3.5 M x 2.5 M | 8.75 SQM | Included | 1006 | Covered Parking | 1006 | 3.5 M x 2.5 M | 8.75 SQM | Included | 107 | Covered Parking | 107 | 3.5 M x 2.5 M | 8.75 SQM | Included | 207 | Covered Parking | 207 | 3.5 M x 2.5 M | 8.75 SQM | Included | 307 | Covered Parking | 307 | 3.5 M x 2.5 M | 8.75 SQM | Included | 407 | Covered Parking | 407 | 3.5 M x 2.5 M | 8.75 SQM | Included | 507 | Covered Parking | 507 | 3.5 M x 2.5 M | 8.75 SQM | Included | 607 | Covered Parking | 607 | 3.5 M x 2.5 M | 8.75 SQM | Included | 707 | Covered Parking | 707 | 3.5 M x 2.5 M | 8.75 SQM | Included | 807 | Covered Parking | 807 | 3.5 M x 2.5 M | 8.75 SQM | Included | 907 | Covered Parking | 907 | 3.5 M x 2.5 M | 8.75 SQM | Included | 1007 | Covered Parking | 1007 | 3.5 M x 2.5 M | 8.75 SQM | Included | 108 | Covered Parking | 108 | 3.5 M x 2.5 M | 8.75 SQM | Included | 208 | Covered Parking | 208 | 3.5 M x 2.5 M | 8.75 SQM | Included | 308 | Covered Parking | 308 | 3.5 M x 2.5 M | 8.75 SQM | Included | 408 | Covered Parking | 408 | 3.5 M x 2.5 M | 8.75 SQM | Included | 508 | Covered Parking | 508 | 3.5 M x 2.5 M | 8.75 SQM | Included | 608 | Covered Parking | 608 | 3.5 M x 2.5 M | 8.75 SQM | Included | 708 | Covered Parking | 708 | 3.5 M x 2.5 M | 8.75 SQM | Included | 808 | Covered Parking | 808 | 3.5 M x 2.5 M | 8.75 SQM | Included | 908 | Covered Parking | 908 | 3.5 M x 2.5 M | 8.75 SQM | Included |
Particulars of Facilities | Status of the facility | Brief description of facility |
---|---|---|
Drinking Water Facility | Ground Water | Copy of Consent Letter |
Fire Fighting Facility | Yes | STAIRCASE, FIRE EXTINGUISHER, SPRINKLER |
Emergency Evacuation Services | Yes | STAIRCASE |
Use of Renewable Energy | No | |
Lift Facility | Yes | 4 NOS OF LIFT (1 STRECHER & 3 NOS 6 PASSENGER CAPACITY) WITH ARD FACILITY |
Market Complex | No | |
Community Hall | Yes | 68.58 SQM COMMUNITY HALL WITH TILE FLOORING |
Gymnasium | No | |
Swimming Pool | Yes | 12.7M X 7.7 M SWIMMING POOL |
Play Ground | No | |
Park/Garden | No | |
Plantation Area | Yes | 288 SQM |
Others(Please Specify) | No | |
Internal Road | Yes | 6 MTR WIDTH & 211 MTR LENGTH INTERNAL ROAD WITH CONCRETE FLOORING |
External Road | Yes | 12.19 MTR WIDE EXTERNAL ROAD ADJACENT TO PROJECT PLOT |
Elecricity Supply | Yes | Copy of Consent Letter |
Other Amenities | No |
Generated by pacms.orera.in on date: 2024-05-09